The calibration key apc sends does the same thing as apcfix or hyperterminal resets the battery constant. Configuring and using hyperterminal with serial devices. This is probably my favorite alternative to hyperterminal. I have an apc ups and the software that comes for it wont install. Next pop the top off the ups theres several screws around the ups which hold the black top cover on. The server and the ups are connected with genuine apc serial signaling cable. Open hyperterminal, enter apc ups for the session name. Kalibracja ups apc smart 2200 rm piotr kujawski sq2lyh.
Hyperterminal windows 7, 8, 10, vista download free trial. There are three ways program the smartups xl to recognize the appropriate number of external batteries. Make sure that there is no application that is using the serial port. Apc smart ups serial connection on windows server 2012 r2. Use hyperterminal to changereset apc ups battery constant. Apc back ups hs 500 is a nice ups with remote control via web. If you need hyperterminal to control serial devices, there is a way to get it back. Ever since i was able to reproduce this with multiple 3000s and multiple wrong serial cables, i am terrified to use anything other than a cable from apc, designed for the model i am. Set the port parameters to 2400 baud, 8 data bits, no parity, 1 stop bit, xonxoff. Hyperterminal overview hyperterminal is a program that you can use to connect to other computers, internet telnet sites, bulletin board systems bbss, online services, and host computers, using either your modem or a null modem cable. Anyway, id launch hyperterminal and choose new connection, point to com1, change the connection options to 8 data bits, no parity, 1 stop bit and no flow control.
Use the erase c or e read the menu command to erase the chip, ready for programming. Oct 01, 2015 in prior versions of windows there were properties pages for the use of an ups and i just wondered if 10 does. Apc backups hs 500 is a nice ups with remote control via web. Apc ups windows hyperterminal software commands selectiondedal. It displays status information, such as battery voltage or backup operating mode and can shutdown the host computer, should the ups run out of battery. My 2 previous videos on apc soft mod using hyperterminal. Apc network management card cli setup posted on november 15, 20 by adam in this quick article i will give you a crash course in the cli and cover the basic ip setup of one of these units. View a list of all the cli commands available to your account type. Mar 27, 2011 switch off the ups once again till you hear a click. Hypoterminal is the simplest terminal software to communicate through com port. Hyperterminal trial hyperterminal free trial for windows 10, 8, 7, vista, and xp. Turn on the ups again and connect a computer with windows 9598me, windows nt 4.
Using windows tm hyperterminal to play with steppers. You then need to add network management card to ups and use apc network shutdown instead of powerchute. Heres the information on the elusive apc smart signalling protocol used by their higher end units backups pro, smartups, matrixups, etc. The location of the label as well as letter and number sequences will vary by model and product type. Take special care what commands you enter because it is possible to cause the ups to suddenly shutdown or, in the worst case, modify the ups in such a way as to permanently disable it. Apc ups software mod using rs232 com port windows 10. Hyperterminal is a communications program that is included free with windows 95 and later. For more detailed instructions and information about each of the rs232 commands listed below, please refer to the original cm1164 user manual. For example, if you are running a serial version of apc s powerchute software, the apc ups service must be stopped prior to running the terminal program. Nov 18, 2012 linux comes with gpl licensed open source apcupsd server daemon that can be used for power mangement and controlling most of apcs ups models on linux, bsd, unix and mswindows operating systems. In windows 7, vista, and 10, you will no longer find the hyperterminal program. For testing you can use putty and set the port settings to 24008none1xonxoff. In order to fit into or remove devices from the smartslot of the ups, please shut off all connected load, switch off the ups, pull the power plug of the ups and switch off the ups once again till you hear a click.
What you see here has been collected from a variety of sources. From the desktop, go to start programs accessories hyperterminal. The slave level converter changes signals from a rs232c interface of a pc to the mbus and in. Without installing any software the apc is not recognized as a device in the device manager. You only need to do this for the larger units like the smt2200. Although the program has some quirks, its handy for sending data to serial displays. The model number is not on the front of the unit, but can be found on a sticker on either the bottom or rear of your product. Configuring apc nmc2 via terminal emulation youtube. In prior versions of windows there were properties pages for the use of an ups and i just wondered if 10 does. How can i adjust the number of battery packs on a smartups xl. How do i configure apc network management card network.
If you need to have ups communicating with agents through network then no, it is not possible with powerchute. Winmust is a free windows application designed to monitor and control a compatible mustek brand ups. The availability of the commands and options below can vary between ups devices. The su700net ups should be connected to hyperterminal now. How to set up and use windows hyperterminal page 33 examples of using hyperterminal with various kits using with kits k121, k122 and k123 start hyperterminal and check that you can communicate with the programmer kit.
If you plug the wrong kind of cable into an apc smart ups xl 3000 it will cut the breaker or just switch off the power, dont remember in the ups instantly. So, i created a script to do it simply from the command line. Using hyperterminal to configure a modem serial emulation software is often required, one of the most frequently used applications is hyperterminal in windows, this example shows windows xp. It has three sockets and you can set them on, off or reboot with webinterface. Im trying to enable my ups apc backups1500 on my new windows xp desktop pc. The procedure for sending at commands to a mobile phone or gsmgprs modem using ms hyperterminal. Recent listings manufacturer directory get instant insight into any electronic component. This manual is available in english on the apc web site. Thank you for your interest in hyperterminal for windows 10 as well as windows 7, windows 8, vista, and older versions.
Get an error disable native windows power management. Before using any terminal emulation program, any services using the com ports must be stopped. Hyperterminal private edition is capable of connecting to systems through tcpip networks, dialup modems, and com ports. I want a windows 2012 r2 server to shutdown on a power breakdown and the remaining power lasts for e. The command line interface, or cli, software is a configuration shell for dlbbased devices. Option 6 enter tty mode communicating with ups this option allows direct interaction with the attached ups using the apc smart protocol commands. Contribute to githubjekaapc ups development by creating an account on github. Switch off the ups once again till you hear a click. Someone installed apc powerchute on windows server 2012. Close hyperterminal, restart the ups service, and rerun power chute software. Rs232 commands after you login via hyperterminal see console login hyperterminal, page 4, you can use the instructions below to send rs232 commands to control the cm1164 from a remote system. Some people analyzed the chatter between powerchute and their hardware. Putty another free telnet and ssh implementation for windows.
These days, the most common reason for including a modem in your computer is to connect to the internet. This tip sheet shows how to configure the program, and lists some known peculiarities. Cli command line interface ligowave knowledge base. When hyperterminal first loads via the hyperterminal link, it will ask for a new connection. Mar 20, 2002 the hyperterminal tool, included with windows 2000, allows you to communicate directly with your systems modem. Hacking the newer apc upss mini workloghowto ocau forums.
There was a ups service in win7s control panel but it isnt there in win10. Hyperterminal manual universitas negeri yogyakarta. The following is a guide as to how to use hyperterminal to communicate with a modem. Apcupsd works with most of apcs smartups models as well as most simple signalling models such a backups, and backupsoffice. You must have the cable with part number 9400024b, 9400024c or 940 1524c 1. Linux comes with gpl licensed open source apcupsd server daemon that can be used for power mangement and controlling most of apcs ups models on linux, bsd, unix and mswindows operating systems. Apc ups windows hyperterminal software commands i am attempting to enable webmanagement functionality on my dell powerconnect2824. For example, if you are running a serial version of apcs powerchute software, the apc ups service must be stopped prior to running the terminal program. Usually, under hyperterminal, windows will have several preconfigured options. Dcim software, and kvmoverip for data centers of all sizes. Therefore the ups should send a message to all servers via. This info was provided by apc tech support back in june of 2006. Walk through of tcpip configuration of apc network management card 2 nmc2 ap9630, ap9631 via terminal emulation command line using the tcpip command to set ip address, subnet mask, and. Also, there are several new alternatives to hyperterminal that are probably better for secure shell access and troubleshooting modems.
If you have a smaller model, flip it upside down and rest it on a towel. Mcp215x40 ds51591a ds51591apage apc hyperterminal commands ecg replacement guide. There are three ways program the smart ups xl to recognize the appropriate number of external batteries. Cli is an alternative way of configuring the device. How to use microsoft hyperterminal to send at commands. Apc told me to install powerchute software drivers. Automating the shutdown of apc ups devices hackaday. Through hyperterminal, you can reset the modem or issue configuration and. However, many people still use their modems to connect to remote devices such as electronic test analyzers, telecommunications equipment, as well as to other modems and thus propel themselves into the world of noninternet online services and bulletin board. Sep 12, 2010 original xp hyperterminal if you just cant live without the original hyperterminal in windows xp, you can actually extract two files from your xp installation and copy them over to windows 7 or vista. It is not intended to be the main device management method. This is the manual for apcupsd, a daemon for communicating with upses uninterruptible power supplies made by american power conversion corporation apc. Setting ip address on a apc ups from command prompy. Aug 19, 2015 walk through of tcpip configuration of apc network management card 2 nmc2 ap9630, ap9631 via terminal emulation command line using the tcpip command to set ip address, subnet mask, and.
If you just cant live without the original hyperterminal in windows xp, you can actually extract two files from your xp installation and copy them over to windows 7810. Enter the administrator login information as displayed in the command prompt. Hyperterminal is used for windows 95, windows 98, windows nt 4. Therefore the ups should send a message to all servers via snmp. Put a valid sim card into the mobile phone or gsmgprs modem. Using hyperterminal or terminal program to change the number of external battery packs hyperterminal. Nov 15, 20 apc network management card cli setup posted on november 15, 20 by adam in this quick article i will give you a crash course in the cli and cover the basic ip setup of one of these units. The hyperterminal tool, included with windows 2000, allows you to communicate directly with your systems modem. From what i can tell by reading the manual i need to connect via the serial port. Refer to your universalstepper manual for the full list of commands available. The install stops with a disable native windows power management statement. For linux users, minicom can be used instead of hyperterminal.
Connect the modem using a modem cable to the serial port on the. Simply copy those files into any directory on your machine and it will work. The views and opinions expressed here represent my own and not those of the people, institutions or organizations that i may or may not be related with. Turn off the ups, disconnect the capacitor and unplug it from the mains. Original xp hyperterminal if you just cant live without the original hyperterminal in windows xp, you can actually extract two files from your xp installation and copy them over to windows 7 or vista. Jan 23, 2019 my 2 previous videos on apc soft mod using hyperterminal. Terminal emulation is a builtin function on most operating systems ex. I use apc upses with windows servers a lot at my work this guy shouldve just bothered with the arduinoapc thing, because the software that. To use ms hyperterminal to send at commands to your mobile phone or gsmgprs modem, you can follow the procedure below. If you have an apcmade ups, whether sold under the apc nameplate or oemed for example, the hp powertrust 2997a, and you want you get it working with a computer running linux, unix, or. Super user, administrator, device user description.
1031 861 1067 1583 562 847 631 68 812 670 769 993 1463 101 36 1265 183 1092 1373 607 96 882 1029 157 1450 286 1182 1033 87 662 17 312 1633 624 1533 999 1553 745 1088 78 491 368 390 1144 356 879 453 1165 691